You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Completes the two keck_ao.md validation-anchor acceptance checks left open at the phase-4 merge (#11, PR #12): astrometric parity of the B1938+666 reduction against HST, and science invariance — a PyAutoLens fit reproducing the published Einstein radius (~0.45"; Lagattuta et al. 2012 / Vegetti et al. 2012).
Plan
Survey MAST for archival HST imaging of B1938+666 (WFC3-IR preferred — reducible by our own phase-2 path for a like-for-like comparison); fall back to published positions.
Audit the NIRC2 narrow-camera plate scale: raw header PIXSCALE 9.952 vs adapter native_scale 9.942 mas (literature spread 9.942/9.952/9.971) — a direct multiplicative bias on any measured Einstein radius; correct the adapter if the audit demands it.
Fit the reduced dataset (10 mas, 39x180s, tier-A PSF) with PyAutoLens: SIE + external shear, Sersic lens light + Sersic source; compare theta_E with published values.
Report here; parity appendix for docs/design/keck_ao.md and any adapter fix go to review before a PR (default present-and-wait — no --auto on this leg).
Check 3 — plate-scale audit (finding, fix gated on review): the adapter's narrow-camera native_scale (9.942 mas, from SHARP paper prose) is wrong for both epochs. Truth: 9.952 mas pre-2015 (Yelda 2010 — B1938 raw headers agree: PIXSCALE 0.009952) and 9.971 mas post-2015 (Service 2016). Effect on shipped phase-4 mosaics: output pixels are truly 10.010 mas, so a naive θ_E reads 0.10% low. Proposed fix: epoch-aware native_scale selected alongside the distortion solution.
Check 3 — geometry leg: no ACS/WFC3 archival imaging of B1938 exists (only 1997–98 WFPC2/NICMOS), so no own-pipeline HST comparison; and the ring is below direct azimuthal-profile detection in the 7,020 s stack (annulus medians at the noise floor) — the model fit carries the geometric test, as in Lagattuta+12.
Check 4 — fit CHECKPOINTED, resumable: Nautilus (SIE+shear+Sersic lens, SersicCore source, 20 mas Chen-style binning, plate-scale-corrected pixels, tier-A PSF) ran ~1 h on CPU; posterior not yet converged; 94 MB checkpoint.hdf5 on disk.
Resume after reset (Nautilus resumes from its checkpoint via the identity-hashed output path):
Inputs it needs are all on disk under prototypes/output/b1938_keck/ (dataset regenerated post-merge) and output/b1938_keck_acceptance/ (checkpoint). Success criterion: θ_E consistent with published ~0.45″.
Activity
Jammy2211 commentedon Jul 9, 2026
Interim results + parked fit (laptop reset)
Check 3 — plate-scale audit (finding, fix gated on review): the adapter's narrow-camera
native_scale(9.942 mas, from SHARP paper prose) is wrong for both epochs. Truth: 9.952 mas pre-2015 (Yelda 2010 — B1938 raw headers agree: PIXSCALE 0.009952) and 9.971 mas post-2015 (Service 2016). Effect on shipped phase-4 mosaics: output pixels are truly 10.010 mas, so a naive θ_E reads 0.10% low. Proposed fix: epoch-awarenative_scaleselected alongside the distortion solution.Check 3 — geometry leg: no ACS/WFC3 archival imaging of B1938 exists (only 1997–98 WFPC2/NICMOS), so no own-pipeline HST comparison; and the ring is below direct azimuthal-profile detection in the 7,020 s stack (annulus medians at the noise floor) — the model fit carries the geometric test, as in Lagattuta+12.
Check 4 — fit CHECKPOINTED, resumable: Nautilus (SIE+shear+Sersic lens, SersicCore source, 20 mas Chen-style binning, plate-scale-corrected pixels, tier-A PSF) ran ~1 h on CPU; posterior not yet converged; 94 MB
checkpoint.hdf5on disk.Resume after reset (Nautilus resumes from its checkpoint via the identity-hashed output path):
Inputs it needs are all on disk under
prototypes/output/b1938_keck/(dataset regenerated post-merge) andoutput/b1938_keck_acceptance/(checkpoint). Success criterion: θ_E consistent with published ~0.45″.docs: Keck per-exposure frame products — feasibility verdict GO, gated (